HOT PIPE COATING is designed to control heat transfer on surface temperatures up to 370oC. It is waterborne and extremely lightweight in appearance. HOT PIPE COATING offers a Green , non-flammable, non-toxic formula for high temperature surface applications.
HOT PIPE COATING was engineered to be applied over hot pipes or other high temperature surfaces to achieve instant adhesion while immediately lowering the temperature of the hot surface. HOT PIPE COATING is waterborne to offer a non-flammable, non-toxic formula for high heat situations.
WHAT SOLUTION DOES THIS OFFER YOU?
HOT PIPE COATING is an insulation system over hot pipes, tanks, and valves
HOT PIPE COATING blocks heat migration into cold tanks, lines, and valves
HOT PIPE COATING can be used to block conductive, convective and radiational heat
HOT PIPE COATING is an ideal solution when a hot system cannot be shut down
HOT PIPE COATING can be used as a base/primer or can be built up in layers for additional protection
HOT PIPE COATING is easily applied using a texture sprayer, and can be applied over metal, concrete, wood, and other substrates.
BENEFITS
HOT PIPE COATING is easy-to-apply directly on to hot pipes while pipes are still operational
HOT PIPE COATING increases insulation with each additional layeroC additional coats immediately reduce surface temperature and loss of heat
HOT PIPE COATING is long lasting oC Does not absorb humidity or lose insulation value when supported by an overcoat of RUST GRIP or ENDU PRODUCTS
HOT PIPE COATING is a safe, non-flammable and non-toxic solution
HOT PIPE COATING can be sprayed to fit over any configuration or shape, making it possible to reach the most difficult places in highly complex environments
HOT PIPE COATING
TECHNICAL SHEET
DESCRIPTION
HOT PIPE COATING is designed to control heat transfer on surface temperatures up to 700 F (370oC). It is waterborne and extremely lightweight in appearance. HOT PIPE COATING uses a special acrylic resin blend with specific ceramic compounds added to provide a non-conductive block against heat transfer. HOT PIPE COATING offers a Green , non-flammable, nontoxic formula for high heat surface applications over standard steam pipe or oven wall construction. HOT PIPE COATING is easily applied using a texture sprayer, and can be applied over metal, concrete, wood, and other substrates. If HOT PIPE COATING is to be applied over flat steel surfaces, contact SPE for instructions.
TYPICAL USES
As an insulation system over hot pipes, tanks, and valves
To block heat migration into cold tanks, lines, and valves
As a system to block conductive and convective heat
Easily applied when a hot system cannot be shut down
APPLICATION METHOD
HOT PIPE COATING should only be used for applications less than 700 F (370oC) unless directed by manufacturer. HOT PIPE COATING can be used for applications over 700F (370oC) up to 900 F (482oC) but only according to the manufacturer's instructions. HOT PIPE COATING can be applied to metal, concrete, masonry and wood. The application is applied using a texture sprayer. For specific instructions on surface preparation, mixing and application, please refer to the SPE Application Instruction sheet for HOT PIPE COATING. If HOT PIPE COATING is applied on surfaces outdoors, you must overcoat the HOT PIPE COATING with SUPER THERM, ENDUROOF, RUST GRIP or ENAMO GRIP according to what is needed (please contact SPE for further instructions). It cannot be left uncoated and left exposed to weather conditions. It is light-weight to insulate, which leaves it vulnerable to weather conditions. HOT PIPE COATING must be completely dry before applying top coat.
NOTE: In situations where there is continuous cycles causing movement, and/or risk of contraction and/or expansion, or regular handling/impact of the pipe is unavoidable, please contact SPE for further instructions to support and protect the application of HOT PIPE COATING.
TESTS AND CERTIFICATIONS
ISO 8302/ASTM C 177 oC Thermal Conductivity (0.063 W/mK @ 86 F/300C)
ASTM E 84 oC Class A
ISO 8302oC Thermal Conductivity
IMO oC MSC.61(67) Smoke and Toxicity Test
HOT PIPE COATINGTM
TECHNICAL SHEET
Marine Approvals oC American Bureau of Shipping;
USDA Approved
MINIMUM SPREAD RATES (mil thickness)
23.0 sq. ft./gal = 50 mils dry film thickness (2.14 m2/gal = 1,27 mm DFT)
11.5 sq. ft./gal = 100 mils dry film thickness (1.07 m2/gal = 2,54 mm DFT)
5.75 sq. ft./gal = 200 mils dry film thickness (0.53 m2/gal = 5,08 mm DFT)
4.7 sq. ft./gal = 250 mils dry film thickness (0.44 m2/gal = 6,35 mm DFT)
PHYSICAL DATA
Solids: By Weight: 47.0% / By Volume: 71.00%
Dry Time: If between 200-300 F (93-150oC); 10-30 minutes per coat, or until steaming action
has finished.
Lead and chromate free
Water-borne
Cures by evaporation
Weight: 5.0 lbs. per gallon (600 gr/lit)
Vehicle Type: Urethane / Acrylic Blend
Shelf Life: Up to 1 year if unopened under appropriate storage conditions (See SDS)
VOC Level: 25.1 grams/liter ; 0.209 gals/lbs
pH: 8.5-9.0
USDA Approved
Maximum Surface Temperature when applying: 700 F (370oC)
Minimum Surface Temperature when applying: 40 F (5oC)
Maximum Surface Temperature after curing: 700 F (370oC)
HOT PIPE COATING will not totally burn. Any initial flame will burn off the surface resin
before charring and blocking the flame.
SAFETY PRECAUTIONS
Do not take internally. Avoid contact with eyes. If solution does come in contact with eyes, flush
immediately with water and contact a physician for medical advice. Avoid prolonged contact with
skin or breathing of spray mist.
KEEP OUT OF REACH OF CHILDREN.
LIMITATION OF LIABILITY: All recommendations or suggestions relating to the use of the products, whether in technical documentation, or in response to a
specific enquiry, or otherwise, are based on data which to the best of our knowledge is reliable. The products and information are designed for users having
the requisite knowledge and industrial skills, and the end-user has the responsibility to determine the suitability of the product for its intended use. SPE has
no control over either the quality of condition of the substrate, or the many factors affecting the use and application of the product. Therefore, SPE does not
accept any liability arising from loss, injury, or damage resulting from such use or the contents of this data sheet. The information contained in this data sheet
is subject to modification as a result of practical experience and continuous product development. This data sheet replaces and annuls all previous issues
and the user has the responsibility to ensure that this sheet is current prior to using the product.
V-4-7-15 Apr-15